生物传感器快速检测血液乙醇含量的研究进展
张宇航;杨晓炜;张慧;石文秀;侯思雨;荣胜忠;潘洪志;刘凤海;
摘要(Abstract):
血液乙醇含量是酒驾和醉驾判定的重要依据,是法医学诊断的一个难题,传统分光光度法、气相色谱法和酶学法无法满足社会发展需要。新型生物传感器快速检测乙醇浓度成为学者研究热点,本文对今年来国内外研究进展进行综述。
关键词(KeyWords): 乙醇;生物传感器;检测;血液
基金项目(Foundation): 黑龙江省大学生创新创业训练计划项目(201610229015);; 国家自然科学基金(81673229)
作者(Authors): 张宇航;杨晓炜;张慧;石文秀;侯思雨;荣胜忠;潘洪志;刘凤海;
DOI: 10.13799/j.cnki.mdjyxyxb.2017.03.046
参考文献(References):
- [1]World Health Organization.Action needed to reduce health impact of harmful alcohol use[N/OL].2011[2013-08-11].
- [2]MARINIS B,MARTIN C.Automated headspace solid-phase microextraction and capillary gas chromaography analysis of ethanol in postmortem specimens[J].Forensic Sci Int,2002,128(3):115-119.
- [3]陈丽平.十一届全国人大常委会第十六次会议刑法修正案(八)草案首次审议[J].法制资讯,2010,8:45-51.
- [4]李世杰,郑雯,冯其光.血液中乙醇浓度检测方法[J].预防医学情报杂志,2007,23(1):124-126.
- [5]左保林.人血中乙醇含量的分光光度法检测[J].刑事技术,1995(2):12-13.
- [6]刘军生,杜书明,钱义.血清中甲醇和乙醇的气相色谱法.中华劳动卫生职业病杂志,2005,23(1):69-70.
- [7]中华人民共和国公安部.血尿中乙醇、甲醇、正丙醇、乙醛、丙酮、异丙醇、正丁醇的定性分析及乙醇、甲醇、正丙醇的定量分析方法:GA中华人民共和国公共安全行业标准,GA/T105-1995,2009.
- [8]CORDELL R L,PANDYA H,HUBBARD M,et al.GC-MS analysis of ethanol and other volatile compounds in micro-volume blood samples-quantifying neonatal exposure[J].Anal Bioanal Chem,2013,405(12):4139-4147.
- [9]XIAO H T,HE L,TONG R S,et al.Rapid and sensitive headspace gas chromatography-mass spectromery method for the analysis of ethanol in the whole blood[J].J Clin Lab Anal,2014,28(5):386-390.
- [10]STOWELL A R,GAINSFORD A R,STOWELL RG.New Zealand’s breath and blood alcohol testing programs:further data analysis and forensic implications[J].Forensic Sci Int,2008,178:83
- [11]王向阳.乙醇氧化酶法测定血清中乙醇含量[J].临床检验杂志,2002,20(4):208-210.
- [12]覃柳,刘仲明,邹小勇.电化学生物传感器研究进展[J].中国医学物理学杂志,2007,24(1):60-62.
- [13]冯东,王丙莲,梁晓辉,等.生物传感器法快速测定酒中乙醇含量[J].酿酒科技,2012(2):86-88.
- [14]谢国民,熊兴良,罗鹏,等.一种基于酶传感器的血酒精便携式检测仪的研究[J].传感器与微系.2008,27(8):42-44.
- [15]张维成,何亚明,吕跃钢,等.流动注射分析-乙醇生物电极法快速测定发酵样品中乙醇含量[J].分析测试学报,1998,17(4):22-25.
- [16]李莎,王艳艳,赵紫霞.基于纳米材料、聚电解质制备高性能乙醇生物传感器[J].分析化学,2008,36(2):227-230.
- [17]TAN L,LI L,PENG Y,et al.Synthesis of Au@Pt bimetallic nanoparticles with concave Au nanocuboids as seeds and their enhanced electrocatalytic properties in the ethanol oxidation reaction[J].Nanotechnology,2015,26(50):401-505.
- [18]TAO B,ZHANG J.An amperometric ethanol sensor based on a Pd-Ni/SiN Ws electrode[J].Sensor Actuat B-Chem,2009,142:298-303.
- [19]LIU Y,ZHAN L.Enzyme-free athanol sensor based on electrospun nickel nanoprticle-loaded carbon fiber paste electrode[J].Anal Chim Acta,2010,663:153-157.
- [20]CHINNADAYYALA S R,SANTHOSH M,SINGH N K,et al.Alcohol oxidase protein mediated in-situ synthesized and stabilizedgold nanoparticles for developing amperometric alcohol biosensor[J].Biosens&Bioelectron,2015(69):155-161.
- [21]JAVIER P M,LUZ M M.Alchol dehydrogenase amperometric biosensor based on a colloidal gold-carbon nanotubes composite electrode[J].Electrochim Acta,2008(53):4007-4012.
- [22]VIJAYA K U,MARA A R,CsO regi E,et al.Alcohol biosensors based on coupled oxidase-peroxidase system[J].Anal Chim Acta,1996(327):223-234.
- [23]LYUDMYLA V S,ALEXEY P S.Amperometric biosensor for ethanol detection baesd on alcohol oxidase immobilized within electrochemically deposited Resydrol film[J].Mat Sci Eng C,2006(26):411-414.
- [24]ANA M A,MIGUEL D,PRAZERES F.Ethanol biosensors based on alcohol oxidase[J].Biosens&Bioelectron,2005(21):235-247.
- [25]LI C,CHEN Y.Preparation of multiwalled carbon nanotube-chitosan-alcohol dehydrogenase nanobiocomposite for amperometric detection of ethanol[J].Sensor Actuat B Chem,2009(138):518-523.
- [26]JIA J,HUANG W.Determination of alcohol using a Ni-Ptalloy amperometric sensor[J].Thin Soild Films,2008(516):5210-5216.